Brand Name : Coolent
Model Number : CYAT40D/U
Certification : ISO/CE
Place of Origin : China
MOQ : 1Unit
Price : to be Negotiated
Payment Terms : T/T, L/C
Supply Ability : 1000/Month
Delivery Time : 20-40days
Packaging Details : Standard export package
Mounting : Floor Standing
Type : Close Control Unit Control CCU
After-sales service provided : Engineers available to service machinery overseas
Operating voltage : 380/400 VAC,230 VAC,220V
Product name : Data Center Cooling Unit
Refrigerant : R22(R407C/R410A)
Application : Data Center, IT room , Computer room, Cold/hot aisle
Airflow : 2000~50000 m3/h
Close Control Unit Air Conditioner Cooling Type For Air Cooled To Meet Various Application Requirements
Products Introduction
Coolnet CCU air conditioner series high-precision Lab air conditioner is developed to meet the high-precision temperature and humidity requirements in special environments. The temperature control accuracy reaches ±0.2°C, and the humidity control accuracy reaches ±2%. It can be widely used in precision instrument laboratories,textile workshops, paper workshops, tobacco companies, archives,etc. | ![]() |
Air Supply Method
Advantage
Excellent control logic. Accurate, safe and energy-saving variable frequency control logic ensures that the target ambient temperature control accuracy reaches ± 0-2°C, and the humidity control accuracy reaches ± 2%.
Quick response. Real-time monitoring of environmental temperature and humidity changes, quickly adjust the output of cooling, heating, humidification, and dehumidification to adapt to the load demand.
High quality accessories. The unit adopts high-quality components,such as page flow inverter compressor, EC fan, electronic expansion valve, SCR electric heating, etc. to ensure the stable performance of the whole machine.
Human-machine interface is friendly. 7-inch touch screen controller,easy to set up, with monitoring and group control functions, to meet the various needs of users. | ![]() |
Technical Parameters
Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
Power Supply | 380V 3Ph-50HZ | |||||||||||||
Air Discharge | Upflow/Downflow | |||||||||||||
Cooling Capacity :24℃/50%RH | ||||||||||||||
Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
Compressor Hermetic scroll | ||||||||||||||
Refrigerant | R407C | |||||||||||||
Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 |
Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 |
Material | PTC | |||||||||||||
Humidifier Section Electrode type | ||||||||||||||
Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 |