Brand Name : COOLNET
Model Number : XR023A, XR040A
Certification : CE,ISO
Place of Origin : CHINA
MOQ : 1set
Price : 1800-30000USD
Payment Terms : T/T, L/C
Supply Ability : 300 PCS PER MONTG
Delivery Time : 20-35working days
Packaging Details : Packed in plywooden case, standard export package
Name : In-Row Air Conditioning Units
Mounting : Floor Standing
Cooling capacity : 20-40KW
Voltage : 380/400 VAC,230 VAC,220V
Fan type : Axial Fan,Direct driven or belt driven,direct driven/belt driven/AC/EC plug fan,AC direct drive fan
Airflow : 2000~50000 m3/h
Refrigerant : R410A/ R407C
Application : Data Center, IT room , Computer room, Server room
Row Based Cool Row Precision Airconditioning Units For Server Room
Row Based Cool Row Precision Air Conditioning Unit For Server Room
Product Introduction In-row air conditioners are also called in-row air cooling units, or in-row refrigeration units. They are precision refrigeration systems specifically designed for high-heat-density racks. They are placed directly between the rows of server cabinets and dissipate heat directly near the heat source. Generally, the compressors of air-cooled in-row airconditioning units use variable-capacity digital scroll compressors, and the fans use EC fans. The whole machine can adjust the cooling capacity output according to the heat load in the channel. In-row air cooling units are widely used in places, such as condition containerized data centers, various modular data centers, data centers with low PUE requirements, local hot spots in computer rooms, high heat density areas in medium and large computer rooms, and computer rooms Data centers with tight area, etc.
Applications Biochemical culture room Power substation and substation Hospital, operating room, laboratory Medium and large computer rooms and data centers Satellite ground station, program-controlled exchange room Museums, money-printing factories, banks, wine cellars Electronics manufacturing, biopharmaceutical, food manufacturing
Technical specifications (indoor unit)
| ![]() |
Features
![]() |
|
Technical Parameter
Model | CRA013A | CRA020A | CRA040A | CRA050A | CRA060A |
Air supply | Front/Side | Front/Side | Front | Front | Front |
Power supply | 380VAC/3Ph/50Hz | ||||
Cooling capacity-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Sensible cooling-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Compressor | |||||
Refrigerant | R410A | ||||
Quantity | 1 | ||||
Fan | |||||
Fan type | EC Centrifugal fan | ||||
Quantity | 4 | 5 | 2 | 3 | 3 |
Air volume-m3/h | 3200 | 5000 | 8800 | 11000 | 12500 |
Heater | |||||
Heat type | PTC | ||||
Capacity-KW | 2 | 3 | 6 | 6 | 6 |
Humidification | |||||
Capacity-KW | 1 | 1.5 | 3 | 3 | 3 |
Certificates
Factory Details
Packing & Delivery
Case
![]() |
Row Based Cool Row Precision Air Conditioning Units For Server Room Images |